MultiStatic Regression Joints
MultiStatic Regression Joints
MultiStatic Regression Joints
Functional limitations: joint mobility and muscle tone.
Intended use: Treatment of correctable contractures.
Intended use: Treatment of correctable contractures.
The MultiStatic Regression Joint enables fast, effi cient and adequate static treatment of contractures - mainly due primarily to orthopedic injuries or diseases - utilizing HLBS* principles. The angle of the joint is set by an eccenric axis. This continuously adjustable static extension or fl exion joint is used in orthoses for both children and adults.
* HLBS = High Load Brief Stretch
Article/size chart
{Label:Open}
Article | Unit | Size | Side | Total lenght | Bar width | Height | Upright thickness | Weight | Joint head diameter |
---|---|---|---|---|---|---|---|---|---|
MS02B-09 | stuk | X-small | universal | 100 mm | 9 mm | 6,5 mm | 1,5 mm | 14 g | 11 mm |
MS03B-12 | stuk | small | universal | 400 mm | 12 mm | 8,5 mm | 2 mm | 83 g | 19 mm |
MS04B-16 | stuk | medium | universal | 400 mm | 16 mm | 9,5 mm | 2 mm | 121 g | 25 mm |
MS05B-19 | stuk | large | universal | 400 mm | 19 mm | 10,5 mm | 2 mm | 151 g | 30 mm |
Features
{Label:Open}
- Easy angle adjustment due to optimally positioned joint axis
- Can be used in flexion and Extension
- Range of motion from +120° to -120°
- Joint head and axle hardened
- Integrated bars
- Material: stainless steel
Product Functions
{Label:Open}
Continuously adjustable static extension or flexion of the joint.
Benefits in achieving therapy goals
{Label:Open}
- Improvement/rehabilitation of joint mobility
- Improvement of the resting posture
Indications / Diagnoses
{Label:Open}
- Amputation (ICD10: T14.7)
- Apoplexy (CVA) (ICD10: I64)
- Cerebral palsy (ICD10: G80.9)
- Cranial cerebral trauma (ICD10: S06.9)
- Dystrophies
- Fracture (ICD10: T14.2)
- Multiple sclerosis (ICD10: G35)
- Spina Bifida (ICD10: Q05)
- Status after joint surgery
- Status after ligament rupture
- Status after paraplegia
Contra indications
- Ankylosis (ICD10: M24.69)
- Fibrosis (ICD10: M35)
- muscles and bones deformation
- Ossification (ICD10: M61.9)
- Poor blood circulation
Documents
{Label:Open}
Accessories
{Label:Open}
MultiStatic Alignment Unit
Intended use: Alignment unit for correct alignment of MultiStatic joints on to the cast.
T-Bar
Intended use: T-bar for correct alignment of joints on the positive Cast.
FreeMotion Free Movable Joints
Intended use: single-axis free motion joint can be used individually, or as a companion joint on the contralateral side to improve the torsional rigidity.
STL files
{Label:Open}